| Management number | 250376344 | Release Date | 2026/09/17 | List Price | US$10.93 | Model Number | 250376344 | ||
|---|---|---|---|---|---|---|---|---|---|
| Category | |||||||||
ATC Power ModuleModule description:1. Maximum load of normally open interface: AC 250V/10A,DC30V/10A;2. Chip mounted optocoupler isolation, strong driving ability andstable performance; Trigger current 5mA3. Module working voltage: 5V / 12V / 24V4. The module can be triggered by setting high level or low levelthrough ;5. Fault tolerant design, even if the control line is broken, the relaywill not act;6. Power indicator (green), relay status indicator (red)7. The interface design is user-friendly, and all interfaces can bedirectly connected and led out through the wiring terminal forconvenience.8. There are 4 fixing holes, 3.1mm, with a spacing of44.5*20.5mmManual measurement, there will be errors!Interface Description:1. DC+:connected to the positive pole of the power supply (the voltageis 5V, 12V and 24V according to the relay requirements)2. DC-:connected to negative pole of power supply3. In: high or low level control relay can be engaged Relay output:1. No: normally open interface of relay. The relay is suspended beforeclosing, and is short circuited with com after closing2. COM:relay common interface3. NC:normally closed interface of relay. The relay is short circuitedwith com before closing and suspended after closing High and lowlevel trigger selection terminal:1. When the is short circuited with low, it is triggered at lowlevel;2. When the is short circuited with high, it is triggered at highlevel.1. The module adopts relay, and the maximum load of normally openinterface: AC 250V/10A,DC 30V/10A;2. Chip mounted optocoupler isolation, strong driving ability andstable performance; Trigger current 5mA3. Module working voltage: 5V/12V/24V4. The module can be triggered by setting high level or low levelthrough ;5. Fault tolerant design, even if the control line is broken, the relaywill not act;6. Power indicator (green),relay status indicator (red)7. The interface design is user-friendly, and the interface can be ledout directly through the wiring terminal, which is very convenient8. Module size: 50mm*41mm*18.5mm (L*w*h)9. Four fixing holes are set, with holes of 3.1mm and spacingof 44.5mm*35.5mmManual measurement,there will be errors!Module interface:1. DC +: connected to the positive pole of the power supply (the voltageis 5V, 12V and 24V according to the relay requirements)2. DC-:connected to negative pole of power supply3. In1: 1 signal trigger end, which can set high or low level tocontrol relay pull in4. In2: 2-way signal trigger end, which can set high or low level tocontrol relay pull inRelay output:1. No1: 1-way relay normally open interface. The relay is suspendedbefore being pulled in, and is short circuited with COM1 after beingpulled in2. COM1: common interface of 1-way relay3. NC1: 1-way normally closed interface of relay, which is shortcircuited with COM1 before pulling in and suspended after pulling in4. NO2: normally open interface of 2-way relay. The relay is suspendedbefore being pulled in, and is short circuited with com2 after beingpulled in5. Com2: common interface of 2-way relay6. NC2: normally closed interface of 2-way relay. The relay is shortcircuited with com2 before pulling in and suspended after pulling inHigh and low level trigger selection terminal:1. S1 is the high and low level trigger selection of relay;2. S2 is the high and low level trigger selectionof 2-way relay;3. When com and low are short circuited, thecorresponding relay is triggered at low level,and when com and high are short circuited, it is triggered athigh level1. The module adopts relay, normally open interface, maximum load:AC 250V / 10A,DC 30V / 10A2. SMD optocoupler isolation is adopted, with strong driving ability,stable performance and trigger current of 5mA3. The working voltage of the module is 5V, 12V and 24V4. Each circuit of the module can be triggered by setting high level orlow level through 5. Fault tolerant design, even if the control line is broken, the relay willnot act6. Power indicator (green), 4-way relay status indicator (red)7. The interface design is user-friendly, and all interfaces can be led outdirectly through the wiring terminal, which is very convenient8. Module size:75mm*52mm*18.5mm (L*w*h)9. Four fixing holes are set, with holes of 3.1mm and spacing of67mm * 44.5mmManual measurement, there will be errors!Interface Description:1. DC +: connected to the positive pole of the power supply (the voltageis 5V, 12V and 24V according to the relay requirements)2. DC -: connected to negative pole of power supply3. In1-in4: according to the setting of each circuit, the pull-in ofcorresponding relay can be controlled at high or low levelRelay output:There are 12 wire interfaces, and all interfaces can be directly connectedand led out, which is convenient for users.1. No1 -- No4:normally open interface of relay. The relay is suspendedbefore closing, and is short circuited with com after closing2. COM1 -- COM4 relay common interface3. NC1 -- NC4: normally closed interface of relay, which is shortcircuited with com before pulling in and suspended after pulling in.High and low level trigger selection terminal:1. S1-S4 are the high and low level trigger selection of relay 1-4 in turn;2. When com and low are short circuited, the corresponding relay is triggered at low level, and when com and high are short circuited, it is triggered at high level.1. The module adopts relay, and the maximum load of normally openinterface:AC 250V / 10A, DC 30V / 10A;2. SMD optocoupler isolation is adopted, with strong driving ability,stable performance and trigger current of 5mA3. The working voltage of the module can be selected from 5V, 12Vand 24V;4. Each circuit of the module can be triggered by setting high levelor low level through ;5. Fault tolerant design, even if the control line is broken, the relaywill not act;6. Power indicator (green), 8-way relay status indicator (red)7. The interface design is user-friendly, and all interfaces can be ledout directly through the wiring terminal, which is very convenient8. Module size: 141.5mm * 52mm * 18.5mm (length * width * height)9. There are 4 fixing holes, 3.1mm, with a spacing of136mm*44.5mmManual measurement, there will be errors!Module interface:1. DC+:connected to the positive pole of the power supply (the voltageis 5V, 12V and 24V according to the relay requirements)2. DC-:connected to negative pole of power supply3. In1-in8: according to the setting of each circuit, the pull in ofcorresponding relay can be controlled at high or low level.Relay output:There are 24 wire interfaces, and all interfaces can be directlyconnected and led out, which is convenient for users.1. No1 -- No8: normally open interface of relay. The relay is suspendedbefore closing, and is short circuited with com after closing.2. COM1 -- COM8:common interface of relay.3. NC1 -- nc8: normally closed interface of relay, which is shortcircuited with com before pulling in and suspended after pulling inHigh and low level trigger selection terminal:1. S1-s8 are the high and low level trigger selection of relay 1-8 inturn;2. When com and low are short circuited, the corresponding relay istriggered at low level, and when com and high are short circuited, itis triggered at high level.==========Type : RelaySupply Voltage: : AC 250V/10A, DC 30V/10AOperating Temperature: : -40-+85Dissipation Power: : 5WVoltage: : 5V,12V,24V,Contact Load: : High and low level triggerModel Number: : with OptocouplerModel Number3: : Relay ModuleModel Number4: : 1/2/4/6/8Channel Relay Module
| ASIN | B0HC212LXV |
|---|---|
| Model | YVJOEJZQGL |
| Brand Name | YVJOEJZQGL |
| Part Number | YVJOEJZQGL |
| Contact Type | Normally Closed |
| Manufacturer | YVJOEJZQGL |
| Mounting Type | Chassis Mount |
| Connector Type | Clamp |
| Current Rating | 0.01 A |
| Number of Items | 1 |
| Contact Material | Aluminum |
| Specification Met | ABS |
| Contact Current Rating | 1 A |
If you notice any omissions or errors in the product information on this page, please use the correction request form below.
Correction Request Form